Everyone knows that the goal of a fire suppression system is to safeguard both your employees and your property in the event of a workplace fire. However, a system’s ability to perform correctly might be harmed by defects.

The most common difficulties fire safety companies encounter while examining fire suppression system and some preventative measures you may do to avoid them. As the saying goes, a pound of prevention is worth a pound of cure. Let’s get this party started!

The protection of commercial buildings from fire and Fire Maintenance has always remained a top issue in occupational safety and security. The potential harm that a fire can inflict impacts many business owners. To safeguard the safety of their employees and corporate assets, business owners invest in the best fire prevention services. Fire sprinklers are the most effective fire safety technology, according to the NFPA.

Unfortunately, a Fire alarm System, fire sprinkler system, or any other part might fail to owe to unanticipated flaws or situations in rare cases. Sprinkler systems are unlikely to fail if they are well-maintained and inspected by certified personnel regularly. On the other hand, sprinkler system maintenance has been neglected, and the sprinklers haven’t been utilized in a long time, the sprinkler system is more likely to fail.

Blocked pipes

It’s a problem that usually affects sprinkler systems that use water. If the temperature goes below a certain level, the remaining water in the sprinkler pipes may freeze. The pipe may rupture, causing water damage. The sprinkler piping should be kept at or above 40°F, To prevent the valves from freezing according to NFPA rules.

Corrosion

One of the most common causes of sprinkler failure is corrosion. Corrosion can occur in the sprinkler system’s external and internal pipes due to prolonged exposure to numerous environmental variables. It could create leaks or cause the valve to become stuck. According to the National Fire Protection Association (NFPA), if signs of corrosion show during routine inspections, the sprinkler system must be changed since it can compromise its function in an emergency.

Inadequate water supply

If the valve is switched off during routine system maintenance, building construction, or repairing a plumbing leak and a fire breaks out in the building, sprinklers may fail. Although improbable, if the wet fire sprinkler system does not receive enough water to extinguish the fire, it might cause significant damage.

Damaged components like sprinkler heads

Fire sprinkler systems can fail due to a flaw in the system. Damage to sprinkler components, such as sprinkler heads and pipes, or an operational failure during the activation, could cause this. Regular sprinkler inspection, repair, and maintenance by certified personnel may typically prevent these failures. You can also build small protective cages around sprinkler heads to shield them from harm.

Lack of Maintenance

Any component of a fire suppression system, fire extinguisher, or fire sprinkler system can fail if not repaired and maintained regularly. Commercial facilities must have a suitable sprinkler system installed, depending on the nature of the industry, according to local fire safety rules and the NFPA.

These failures can be avoided if the system is maintained regularly. Fire suppression systems repairs should be performed periodically to guarantee that your commercial fire prevention system is ready to handle any emergency. As a result, depending on state fire safety rules, it is advised that you get your fire sprinkler tested every six months or annually by a licensed professional. If your sprinkler system hasn’t been tested in more than six months, contact Fire Serv’s qualified specialists to have it inspected to avoid failure.